Made Proudly in USA of Mil-Spec Components
|
|
Band |
Down lead Length |
Antenna Spacing |
Recommended Antenna Height |
Min. Antenna End Height |
| 17 | 45 FT | 14-15 FT | 25-35 FT | 7-10 FT |
| 20 | 57 FT | 16-18 FT | 25-35 FT | 7-10 FT |
| 40 | 68 FT | 28-34 FT | 25-35 FT | 10-15 FT |
| 80 | 126 FT | 60-64 FT | 40-60 FT | 15-20 FT |
| 160 | 263 FT | 124-128 FT | 60-90 FT | 15-20 FT |
DOWN LEADS, PHASING LINE, COAX SWITCH AND CONNECTORS ARE NOT SUPPLIED.
IAC can supply custom cables and components as required to complete your system Contact IAC for price and delivery.
![]()

Band |
Down lead Length |
Antenna Spacing |
Recommended Antenna Height |
Min. Antenna End Height |
| 17 | 45 FT | 14-15 FT | 25-35 FT | 7-10 FT |
| 20 | 57 FT | 16-18 FT | 25-35 FT | 7-10 FT |
| 40 | 68 FT | 28-34 FT | 25-35 FT | 10-15 FT |
| 80 | 126 FT | 60-64 FT | 40-60 FT | 15-20 FT |
| 160 | 263 FT | 124-128 FT | 60-90 FT | 15-20 FT |
Antenna #1 and antenna #2 down leads must have a velocity factor of 66% and be the exact length as specified in the installation dimensions. The phasing line length can be incorporated in one of the down leads although using connectors allows for manual phase reversal.
DOWN LEADS, PHASING LINE, AND CONNECTORS ARE NOT SUPPLIED
IAC can supply custom cables and components as required to complete your system. Contact IAC for price and delivery.